PDF Catalog
How to work the handle | Name | Administrator (IP: *.49.80.130) | Date | 2015-04-08 20:52 | Hit | 2,519 |
---|---|---|---|---|---|
How to work the handle -How to set the handle for working pressure- At first, we will advise you how to set the pressure 0~100psi, for instance. 1. First, using the pin or point of a knife, take off the 'DRASTAR' sticker attached on the handle. 2. Turn the handle to the clockwise and set the pressure to the level that you need (ex : 100psi). 3. Then, clutch the handle. 4. Using the 14mm socket wrench, turn it counter-clockwise until the 14mm nut is loosened. 5. Remove the 14mm socket wrench, and turn the handle clockwise (right) till it does not move.(*Causion: After installation of the gas regulator, please check the setting pressure of 100psi and required pressure, etc.) 6. While clutching the handle, turn the 14mm nut to the clockwise to fix it. If you adjust according to the above procedure, you can set it so that it can be operating within the pre-setting pressure range between 0~100 psi. |
|||||
File | 판넬마운트 설치법.pdf(560.2K) |
No | Subject | Name | Date | Hit |
---|---|---|---|---|
38 | DRM250_Catalogue (UHP Miniature Regulator)_2024 New Model | Administrator | 24-01-31 | 3,782 |
37 | DRA77_Catalogue (UHP Back Pressure)_2023 New Model | Administrator | 24-01-31 | 92 |
36 | DR75_Catalogue( High Flow Cv2.0)_2023 NEW Model | Administrator | 24-01-31 | 415 |
35 | 2200_Catalogue (UHP Two Stage)_2024 | Administrator | 20-02-10 | 29,028 |
34 | 085_Catalogue (Hydraulic)_2024 | Administrator | 20-02-10 | 549 |
33 | AC720_Catalogue(Automatic Changeover Systems)_2024 | Administrator | 20-02-10 | 7,677 |
32 | DRA500_UHP Catalogue_2024 | Administrator | 18-04-11 | 10,065 |
31 | DR110_Catalogue (3/4", & 1" High_Flow)_2024 | Administrator | 17-12-30 | 3,432 |
30 | 088_Catalogue (Back High Pressure)_2024 | Administrator | 17-12-30 | 1,368 |
29 | AC700_Catalogue(Automatic Changeover Systems)_2024 | Administrator | 17-06-23 | 852 |
28 | DR90_Catalogue_2024 | Administrator | 17-06-23 | 4,335 |
27 | DVS_Core Valve_Catalogue_2024 | Administrator | 15-04-08 | 1,271 |
26 | DR80_Catalogue_2024 | Administrator | 15-04-08 | 6,904 |
25 | Coolant_Catalogue | Administrator | 15-04-08 | 1,084 |
24 | DRH_Gas Heater_Catalogue_2024 | Administrator | 15-04-08 | 980 |
23 | Company Profile_2024 | Administrator | 15-04-08 | 917 |
22 | DRA300_Catalogue (UHP Springless type Regulators)_2024 | Administrator | 15-04-08 | 2,271 |
21 | DRA200_Catalogue (UHP Tied type Regulators)_2024 | Administrator | 15-04-08 | 1,560 |
20 | DRA100_Catalogue (UHP type Regulators)_2024 | Administrator | 15-04-08 | 13,414 |
19 | DRA700_Catalogue (Lock type Regulators)_2024 | Administrator | 15-04-08 | 4,558 |
18 | DR70_Catalogue (1/2", 3/4", 1" High_Flow)_2024 | Administrator | 15-04-08 | 1,045 |
17 | 2000_Catalogue (Two Stage)_2024 | Administrator | 15-04-08 | 4,681 |
16 | 077_Catalogue (Back Pressure)_2024 | Administrator | 15-04-08 | 1,033 |
15 | 092_Catalogue_1/2"_2024 | Administrator | 15-04-08 | 3,943 |
14 | 082_Catalogue (High Pressure)_2024 | Administrator | 15-04-08 | 24,356 |
13 | 072_Catalogue_2024 | Administrator | 15-04-08 | 3,440 |
12 | DR60_Catalogue_2024 | Administrator | 15-04-08 | 1,024 |
11 | Catalogue_2024_PDF | Administrator | 15-04-08 | 5,483 |
10 | VCR type_P810_Pressuer Gauge | Administrator | 15-04-08 | 1,564 |
9 | NPT type_P113_Pressuer Gauge | Administrator | 15-04-08 | 1,543 |
8 | How to work the handle | Administrator | 15-04-08 | 2,520 |
7 | Instructions_2020 | Administrator | 15-04-07 | 2,241 |
6 | Particle Test | Administrator | 15-04-02 | 991 |
5 | Regulator_Body__test_report | Administrator | 15-04-02 | 2,177 |
4 | Helium_leak_test | Administrator | 15-04-02 | 1,035 |
3 | VCR_Fitting | Administrator | 15-04-02 | 1,006 |
2 | H.P.I.C_Grade | Administrator | 15-04-02 | 3,645 |
1 | VCR_Grade_test_report | Administrator | 15-04-02 | 915 |