High Flow Pressure Reducing Regulators

5845214f9b005.gif

  Products Feature

High Flow and High Pressure Regulators(NPT or BSP 1/2″ 3/4″ 1″)

DR70 Series is a NPT or BSP type single-stage high flow pressure reducing regulator suitable for pipeline application where high flow of water, chemical, liquid and gases are being used. Drop-preventing function of DR70 series enables stable and precise regulation of outlet pressure even facing with wide pressure variation at P1.

◈ 1/2”, 3/4”, 1” NPT or BSP type available
◈ Drop-preventing function is built in
◈ Suitable for the industrial control
◈ Inlet pressures are 420bar(6000psi) or 100bar(1450psi) and outlet pressures are 10bar(145psig), 25bar(360psig), 50bar(720psig), 70bar(1000psig), 150bar(2100psig), 250bar(3600psig), and 350bar(5000psig)
◈ Panel mounting and wall mounting bracket available as option
◈ Design proof pressure: 150% of maximum rated

[DRASTAR Regulators are Oil-free]
※ DRASTAR’s all pressure regulators are assembled, cleaned, inspected, and packed in clean-room equipped with clean bench, helium detector, particle counter, ultrasonic cleaner, ultrapure water system, vacuum packaging machine, etc. through oxygen cleaning procedure in compliance with process and regulations indicated in CGA 4.1. and or ASTM G-93 and are free of any grease or oils.

※ Caution: Filtering (gas 7㎛ ~ 15㎛, water 15㎛ ~ 80㎛) is a MUST to use in the general gas application other than high purity gases. Otherwise, it may cause a failure to the regulators. It is strongly recommended to install filter for extension of life span and saving the maintenance expense.

  Ordering Information.

DR702 - S P - 010 - NP 2 - V - H1
BASIS
SERIES
NUMBER
BODY
MATERIAL
VALVE
SEAT
CONTROLLED
PRESSURE
RANGE
INLET
OUTLET
PORTS
INLET
OUTLET
PORTS SIZE
SELF
VENTING
HIGH
TEMPE-
RATURE
DR701 =
Bolt Control

DR702 =
Knob Control
B = Brass
100bar (1500psi)

S = STS 316L
200bar (3000psi)

SH = STS 316L
420bar (6000psi)
P = Teflon

V = Vespel

SH model
Vespel
Standard

 
010=10bar(145psi)
025=25bar (362psi)
050=50bar(725psi)
070=70bar(1000psi)

SH model ONLY
150=150bar(2100psi)
250=250bar(3600psi)
350=350bar(5000psi)

NP = NPT

BS = BSP
1 = 1/2"

2 = 3/4"

3 = 1"
V = Self-
     Venting




Optional
H1 = 120°C

H2 = 250°C

H3 = 320°C

Optional
  ※Note : Self-venting option (V) is not applicable for high pressure of 150bar/250bar/350bar for safety reasons.

 

  Specification

 Ports

 3/4", 1"  Female  NPT & BSP
 DR702-xx-0xx-NPx   NPT
 DR702-xx-0xx-BSx   BSP  
 With Pressure gauge, Filter, Male connect (Optional)  

 Design Proof Pressure

 150% maximun rated

 Leak Rate  Certification

 to 2 x 10-8 atm cc/sec Helium available.

 Body Materials

 DR702-Sx-010-NP3    Stainless steel 316L
 DR702-Bx-010-NP3    Nickel Plated Brass

 Bonnet Material

 Nickel Plated Brass (Stainless steel 316L Optional)

 Diaphragm

 Stainless steel 316L

 Main Valve

 Stainless steel 316L

 Valve Spring

 Stainless steel 316L

 Valve Seat

 Teflon    Standard
 Vespel    Optional
 DR70x-SHV-xxx-xxx  model Only  Vespel

 Outlet Pressure  Ranges

 DR702-Sx-010-xxx    10bar(145psi)
 DR702-Sx-025-xxx    25bar(360psi)
 DR702-Sx-050-xxx    50bar(7205psi)
 DR702-Sx-070-xxx    70bar(1000psi)
 DR702-SHV-150-xxx    150bar(2100psi) SH model Only
 DR702-SHV-250-xxx    250bar(3600psi) SH model Only
 DR702-SHV-350-xxx    350bar(5000psi) SH model Only  

 Operating  Temperature

 -40°C ~ +70°C (-40°F ~ +165°F)   Standard
 DR702-Sx-010-NP3-H1    +120°C   Optional
 DR702-Sx-010-NP3-H2    +250°C   Optional
  DR702-Sx-010-NP3-H3    +320°C   Optional
 +400°C ~ +540°C (+750°F ~ +1000°F)   Optional

 Flow Capacity

 Cv=3.5 Standard  

 Optional

 Panel mounting bracket
 Outlet Gauge etc..

 Weight

 5.4kg

     

    Recommendations to Use


Each product is manufactured since being taken into consideration of the best safety and easy manipulation. However in order to use the regulator in most safe and effective way, you are recommended to use the actual pressure within the range of its 25% ~ 75%. For making precise, smooth movement and to prolong product life, strongly recommended to make a use within above mentioned range.



[ Unit conversion program ]

unit unit conversion
atmosphere atm
bar bar
mbar mbar
kg_f/cm^2 kg_f/cm^2
Pound per Squire Inch PSI (= lb/in^2)
dyne per square centimeter dyne/cm^2
Pascal Pa
Newton per square meter N/m^2
Hecto Pascal hPa
Kilo Pascal kPa
Mega Pascal MPa
수주(水柱)밀리미터 mm H_2O (= mm Aq)
수주(水柱)인치 in H_2O (= in Aq)
수은주(水銀柱)밀리미터 mm Hg (= Torr)
수은주(水銀柱)인치 in Hg